JSB 4200 Series 2, 4, 8 Zone Control PanelEasy to install and use, the Firedex 4200 series of conventional fire panels delivers basic fire detection and alarm facilities at exceptional value for money. Designed with smaller installations in mind, a choice of 2 or 4 zone compact panels are available, each capable of having up to 20 detectors connected per zone.End of line devices for both detector and alarm circuits are conveniently supplied as standard.
Firedex 4200 systems are also easy to use, with a simple 'one-shot' test facility to ensure regular mandatory testing can be quickly and regularly accomplished. Other standard features, such as class change, zone or sounder circuit disabling and programmable relay output facilities complete a highly competitive solution.Features:.Competitive system.Choice of 2 or 4 zone panels.Simple 'one-shot' auto-reset user test facility.Complies with EN54.Programmable fire/fault output relay.Zone/sounder circuit disabling for easy maintenance.Supplied complete with battery and end of line devices.
. Power Supply: Mains 230V ac nominal ± 10%. Working Voltage: 21.5 - 30V dc. Temperature Range: 0 - 40°C. Maximum Humidity: 85% Non-condensing.
Panel Model: 6301 6302 6304. Standby Load (Mains Fail Condition): 90mA 115mA 170mA. Alarm Load (Mains Fail Condition): 210mA 260mA 345mA.
It is designed to be extended easily, where you can create your own custom extensions. BoxBilling- 100% Free & Open Source Platform BoxBilling is equally flexible as WHMCS, but it laid out a little difference in its features. Here the boxbilling.com gives you all for free, but if you want pro version you can buy at the reasonable price. Brennenstuhl pm 230 manual treadmill manual. This upgraded version requires a new minimum system requirements of PHP version of 5.3.7 and PDO supporting.The new version is designed to give what customers want to do like, which includes bug fixes and improvements.
Display: Backlit liquid crystal display 2 lines of 40 characters. Digital Addressable Loops: 1,2 or 4 loops, each with 191 address capacity. Total panel capacity is restricted to 512 Input addresses to comply with EN 54-2. Algo-Tec™ 6000 Protocol. Total Loop Load: 600mA per loop including all loop connected devices.
Protec 6500 Panel
Zones: 32 Zone LED’s plus twin red common fire indicators. Integral Charger: 3A dc Switch-mode. Integral Battery: 10Ah 24V sealed lead acid. Remote Power Supply: The Protec 9000/BC range of power supplies are compatible with the 6300 panels.
Protec 400 Fire Alarm Panel Manual Instructions
Dual path outputs and fault signalling, (4 wire plus 2 wire, 2 primary power, 2 signals, 2 secondary power). Programmable Alarm Outputs: 4 Monitored - Internal sounder circuits (1A rated @ 24V). 1 Set of non-monitored double-pole changeover contacts (1A rated @ 24V).